Cystatin C optimal range and reference range

Compiled by Alina Radu, founder of Sera, from the published sources below · Last reviewed November 9, 2026

Sera's bands for Cystatin C:

  • Optimal 0.6 – 1 mg/L (0.6 – 1 μg/mL); sufficient 0.5 – 1.2 mg/L (0.5 – 1.2 μg/mL); out of range above 1.2 mg/L.

Evidence grade: Published reference interval. A band that primarily reflects a published adult laboratory or population reference interval. It is not necessarily applicable to every assay or laboratory.

All units

UnitOptimalSufficientOut of range
mg/L0.6 – 10.5 – 1.2above 1.2
μg/mL0.6 – 10.5 – 1.2above 1.2

Bounded on the high side only — a low result is not treated as out of range. No source gives a low cystatin C a clinical meaning, and 0.5 mg/L matches no published lower limit.

What the evidence says

KDIGO recommends it specifically to confirm a borderline creatinine-based eGFR before diagnosing chronic kidney disease, because creatinine reflects muscle mass and cystatin C does not. Raised independently by thyroid dysfunction, corticosteroids and obesity, so those have to be excluded before reading it as kidney function. The bands are a laboratory reference interval, not a guideline threshold: Mayo Clinic Laboratories reports up to 1.03 mg/L under age 50 and up to 1.21 mg/L from 50, which is where the optimal and acceptable bands end. A low result has no published meaning and is not flagged.

Sources

What Cystatin C measures

A small protein filtered freely by the glomerulus, used as a measure of kidney function that does not depend on muscle mass.

The answer to creatinine's main weakness: creatinine reflects muscle, so it overstates kidney function in a frail or sarcopenic person and understates it in a muscular one. Cystatin C avoids that, and KDIGO recommends it to confirm a borderline eGFR before labelling someone with chronic kidney disease. It is raised independently by thyroid dysfunction, steroids and obesity.

Related kidney & electrolytes markers

See Cystatin C in the full list of biomarker ranges

About the author

Alina Radu is the founder of Sera and a software engineer. The idea started with her own Hashimoto's tests, scattered across years without the big picture. She is not a clinician: these ranges are compiled from the published sources linked on each page, with every source named. Alina Radu on LinkedIn

This page is a reference for practitioners, not medical advice. Sera's bands are practitioner targets for structured review, not diagnostic thresholds, and Sera does not diagnose or recommend treatment. Read a result alongside the interval printed by the issuing laboratory and the client's history and symptoms. Range set: Sera Production, version 1.0, last reviewed November 9, 2026.