Anti-CCP optimal range and reference range

Compiled by Alina Radu, founder of Sera, from the published sources below · Last reviewed November 9, 2026

Sera's bands for Anti-CCP:

  • Optimal 0 – 20 U/mL (0 – 20 AU/mL); sufficient 20 – 40 U/mL (20 – 40 AU/mL); out of range below 0 or above 40 U/mL.

Evidence grade: Published reference interval. A band that primarily reflects a published adult laboratory or population reference interval. It is not necessarily applicable to every assay or laboratory.

All units

UnitOptimalSufficientOut of range
U/mL0 – 2020 – 40below 0 or above 40
AU/mL0 – 2020 – 40below 0 or above 40

What the evidence says

The 20 U/mL edge is the cut-off the great majority of assays are calibrated to, not a guideline figure; on that scale laboratories such as ARUP report 20 to 39 as weak positive and 40 and above as moderate to strong positive, which is where the acceptable band ends. ACR/EULAR score this marker against the issuing laboratory's own upper limit, so read a borderline value against the interval on the report. Specificity for rheumatoid arthritis is high, around 95%, and antibodies can appear years before joint symptoms do.

Assay: Results differ meaningfully between platforms and methods. Compare against the interval printed by the issuing laboratory before acting on a borderline value.

Sources

  • Cyclic Citrullinated Peptide Antibody, IgG and IgA — ARUP Laboratories, 2026 · Laboratory / reference-interval source19 Units or less is negative, 20 to 39 weak positive, 40 to 59 moderate positive, 60 or greater strong positive. Sera's optimal band ends at the negative cut-off and its acceptable band at the end of weak positive.
  • Rheumatoid Arthritis Classification Criteria — American College of Rheumatology / European League Against Rheumatism, 2010 · Professional societyScores anti-CCP and rheumatoid factor against the issuing assay's own upper limit of normal, separating low-positive (up to three times that limit) from high-positive. Sera's optimal/acceptable split mirrors that tiering; the criteria set no absolute cut-off in U/mL, which is why the marker is flagged assay-dependent.

What Anti-CCP (Cyclic Citrullinated Peptide) measures

An antibody against citrullinated proteins, and the most specific blood marker for rheumatoid arthritis.

Specificity is around 95%, so a clear positive alongside joint symptoms carries far more weight than rheumatoid factor does. It can appear years before symptoms, which is why a positive in someone with vague joint pain is worth acting on. The cut-off differs between assays — read a borderline value against the interval on the report.

Related autoimmune markers

See Anti-CCP in the full list of biomarker ranges

About the author

Alina Radu is the founder of Sera and a software engineer. The idea started with her own Hashimoto's tests, scattered across years without the big picture. She is not a clinician: these ranges are compiled from the published sources linked on each page, with every source named. Alina Radu on LinkedIn

This page is a reference for practitioners, not medical advice. Sera's bands are practitioner targets for structured review, not diagnostic thresholds, and Sera does not diagnose or recommend treatment. Read a result alongside the interval printed by the issuing laboratory and the client's history and symptoms. Range set: Sera Production, version 1.0, last reviewed November 9, 2026.